Summary
California produces ~75% of U.S. peaches, a crop worth >$670 million annually. However, stone fruits like peaches, nectarines, and plums have been linked to Listeria monocytogenes and Salmonella outbreaks, leading to foodborne illness and major economic losses. Hydrocooling, a process that rapidly cools fruit after harvest, is essential to maintain quality but can also spread bacteria if water is not properly sanitized. Chlorine is the main sanitizer used in hydrocooling systems, but its effectiveness depends on factors such as water temperature, organic matter, and chlorine concentration. These factors vary widely in commercial operations, and their combined effects on bacterial survival are not well understood.
This project will study how these key factors influence chlorine stability and pathogen control in laboratory simulations and then test optimized conditions in commercial packing facilities. A safe, nonpathogenic bacterium, Enterococcus faecium, will be validated as a stand-in for Listeria and Salmonella to enable safe in-plant testing. Finally, in-plant validation will be conducted in three California packing facilities to ensure the optimized chlorine strategies work under real-world conditions.
Results will provide stone-fruit growers and packers with science-based guidance to reduce contamination risks, strengthen food safety compliance, and protect consumer health, supporting a safe, sustainable produce supply.
Technical Abstract
Stone fruits are high-value commodities, with California producing ~75% of U.S. peaches and contributing an estimated $671 million to the state economy. Despite their economic importance, stone fruits have emerged as vehicles for Listeria monocytogenes and Salmonella, causing public health concerns and economic losses from multistate outbreaks. Hydrocooling is a critical postharvest operation used to rapidly remove field heat and maintain fruit quality. However, recirculated hydrocooling water can harbor pathogens and facilitate cross-contamination if not properly managed. Chlorine, the primary sanitizer used in industry, is effective but highly sensitive to these operational parameters, which remain poorly characterized under commercial hydrocooling conditions. The overall goal of this study is to evaluate and validate critical operating parameters for chlorine in hydrocooling systems under commercial stone-fruit conditions, to minimize cross-contamination risk and enhance microbial safety of postharvest operations. Specifically, this project aims to optimize chlorine management strategies in hydrocooling systems and validate the effectiveness of selected sanitizer interventions in commercial hydrocooling operations across three representative California stone fruit hydrocooling systems. The research will be conducted in three steps. 1a) Determine the effects of key operational parameters (sanitizer concentration, water temperature, organic load, strain, and contamination levels) on chlorine stability and pathogen inactivation in hydrocooling water under controlled conditions; 1b) Validate the suitability of Enterococcus faecium NRRL B-2354 as a nonpathogenic surrogate for L. monocytogenes and Salmonella in chlorinated interventions under hydrocooling conditions; 1c) Validate optimized chlorine management strategies under three commercial stone-fruit hydrocooling systems in California.
The project will benefit California stone-fruit growers, packers, and shippers, as well as other tree-fruit industries that have similar practice. Outcomes will provide actionable, science-based guidance to enhance food safety, support FSMA compliance, reduce pathogen risks, and improve sustainability. The methods developed will also inform control of other pathogens, strengthening the safety and competitiveness of the U.S. fresh produce supply chain.
Research Objectives
Objective 1. To optimize chlorine management strategies in hydrocooling systems and validate the effectiveness of selected sanitizer interventions in commercial hydrocooling operations across three representative California stone fruit hydrocooling systems. We will address this in three steps.
Obj1a. Determine the effects of key operational parameters (sanitizer concentration, water temperature, organic load, strain, and contamination levels) on chlorine stability and pathogen inactivation in hydrocooling water under controlled conditions. Chlorine is the primary sanitizer used in stone-fruit hydrocooling systems, yet its performance is highly sensitive to operational parameters such as sanitizer concentration, water temperature, organic load, and contamination level, which vary widely across operation stages, days, and facilities. Organic matter from incoming fruits, soil, and debris rapidly consumes FC, while fluctuations in temperature and pH further alter chlorine stability and activity, reducing antimicrobial efficacy and elevating cross-contamination risk. Before in-plant validation, it is essential to determine how these parameters interact and influence chlorine decay and inactivation of L. monocytogenes and Salmonella under controlled conditions, which cannot be isolated in commercial settings. The testing provides a solid foundation for in-plant sanitizer intervention, ensuring that commercial validation trials are grounded in scientifically optimized and industry-relevant conditions. Experimental conditions will reflect operational ranges typical of commercial hydrocooling systems.
Obj1b. Validate the suitability of Enterococcus faecium NRRL B-2354 as a nonpathogenic surrogate for L. monocytogenes and Salmonella in chlorinated interventions under hydrocooling conditions. In-plant testing requires a reliable, non-pathogenic surrogate to safely predict the fate and response of target foodborne pathogens in commercial facilities. E. faecium NRRL B-2354 (E. faecium) is a well-recognized surrogate of Salmonella in low-moisture foods [32-36] and has been demonstrated as a suitable surrogate of L. monocytogenes on apples with chlorine and PAA based sanitizers [37-39], as well as for L. monocytogenes and Salmonella on peach with chlorine [30] in single-use water systems. These studies provide a scientific foundation for safely conducting in-plant sanitizer validation. Its fidelity and suitability for stone-fruit hydrocooling water and peaches in the presence of organic matter will be further verified before commercial testing. Establishing its equivalency under these conditions serves as an essential translational bridge between pathogen reduction studies (1a) and commercial-scale validation (1c), ensuring industry relevance, practical adoption, and integration into food safety management plans.
Obj1c. Validate optimized chlorine management strategies under three commercial stone-fruit hydrocooling systems in California. Building on laboratory optimization (1a) and surrogate validation (1b), optimized chlorine management strategies will be tested under commercial conditions at three representative California stone-fruit hydrocooling systems. Hydrocooling operations present dynamic challenges, including fluctuating organic load, water recirculation, temperature variation, and high fruit throughput, that cannot be fully replicated in the lab. In-plant validation will assess sanitizer stability, pathogen reduction, and cross-contamination control using E. faecium as a surrogate. These in-plant data will confirm the scalability and practicality of optimized chlorine management protocols, providing directly actionable outcomes for industry adoption.
Findings & Recommendations
This project is ongoing. A final report will be provided when the project is finished.